proma thc and 60s plasma cutter

Discussion forum for RazorWeld, Everlast, and all other plasma cutters.
Post Reply
ScottLister
1/2 Star Member
1/2 Star Member
Posts: 8
Joined: Tue Sep 01, 2015 4:39 pm

proma thc and 60s plasma cutter

Post by ScottLister »

I have a 60s plasma cutter and a proma thc. I removed the jumper to obtain the 1/50th divided voltage but I am getting nothing on my thc. My table manufacturer said to use the raw arc voltage with a 100k resistor to fix the problem. When I read in the everlast manual it says the raw arc voltage is already coming through 2 100k resistors. My question is do I need to install another 100k resistor or can I just connect to the raw arc voltage pins on the cpc connector? Any help would be appreciated.


Thanks
Scott
Rodw
4 Star Member
4 Star Member
Posts: 780
Joined: Sun Aug 21, 2016 1:49 am
Location: Brisbane, Australia
Contact:

Re: proma thc and 60s plasma cutter

Post by Rodw »

There is an error in the Everlast documentation. See this thread

http://plasmaspider.com/viewtopic.php?f=111&t=23700

I never got this working properly until I joined 2 x 48 volt power supplies together and put 98 volts through the divider board and measured the output with a voltmeter.
Post Reply

Return to “RazorWeld, Everlast, & All Other Plasma Cutters”