Hobart airforce 40i / miller spectrum x-treme 675 40amp question

Discussion forum for Lincoln & Miller plasma cutters
Post Reply
Ezalyconfuzd1
2 Star Member
2 Star Member
Posts: 57
Joined: Mon Jan 01, 2024 11:54 pm

Hobart airforce 40i / miller spectrum x-treme 675 40amp question

Post by Ezalyconfuzd1 »

I'm having an issue with my Hobart Airforce 40i. It's starting just fine on the first cut, but when it goes to start the second cut I get CUP flash error. Then once the error stops it'll start right up again. Any ideas? New consumables. Also noticed my THC voltage dropped down to 103V instead ofbthe normal 113v on 1/8". Not sure if that has any relevance.
20240212_181941.jpg

You currently do not have access to download this file.
To gain download access for DXF, SVG & other files Click Here

weldguy
4 Star Elite Contributing Member
4 Star Elite Contributing Member
Posts: 1968
Joined: Fri Apr 17, 2009 11:48 am

Re: Hobart airforce 40i / miller spectrum x-treme 675 40amp question

Post by weldguy »

If you have a air pressure gauge at the back of the plasma cutter, what is the input pressure at during the end of the first cut?
Ezalyconfuzd1
2 Star Member
2 Star Member
Posts: 57
Joined: Mon Jan 01, 2024 11:54 pm

Re: Hobart airforce 40i / miller spectrum x-treme 675 40amp question

Post by Ezalyconfuzd1 »

weldguy wrote: Tue Feb 13, 2024 7:56 pm If you have a air pressure gauge at the back of the plasma cutter, what is the input pressure at during the end of the first cut?
Thank you for the response sir. Turns out the return spring inside of the head lost its spring rate when it got too hot and wouldn't return so reset the pilot arch. I just stretched it and so far so good.
weldguy
4 Star Elite Contributing Member
4 Star Elite Contributing Member
Posts: 1968
Joined: Fri Apr 17, 2009 11:48 am

Re: Hobart airforce 40i / miller spectrum x-treme 675 40amp question

Post by weldguy »

Good find! Hope your fix goes the distance for you :Like
Ezalyconfuzd1
2 Star Member
2 Star Member
Posts: 57
Joined: Mon Jan 01, 2024 11:54 pm

Re: Hobart airforce 40i / miller spectrum x-treme 675 40amp question

Post by Ezalyconfuzd1 »

weldguy wrote: Wed Feb 14, 2024 12:35 pm Good find! Hope your fix goes the distance for you :Like
Thank you. So far so good.
Post Reply