I am using a 4x4 plasmacam table with a hypertherm powermax 65. I have suddenly started getting the "severe communication error". the torch tries to initialize but moves about 4 inches and gives the same error, and other times gives an error stating that the noise is within the cutter, parallel port or cables. I have the computer plugged in a surge protector with extra EMI/RFI filter, the torch is plugged in to a different circuit. My table is earth grounded and I have run a wire from the parallel port to the computer. my next thought is to replace the parallel cable even though it is less than a year old...Is there a special kind of cable I need?
HELP!!!
parallel port communication error....
-
- 1 Star Member
- Posts: 21
- Joined: Tue Jun 04, 2013 7:52 pm
- Francisco
- 2.5 Star Member
- Posts: 178
- Joined: Tue Feb 23, 2010 4:17 pm
Re: parallel port communication error....
You need a bidirectional printer cable, IEEE 1284 compliant; this one looks good:
http://www.amazon.com/Belkin-Series-Par ... 0009NNW62/
Cheers!
http://www.amazon.com/Belkin-Series-Par ... 0009NNW62/
Cheers!